AUTODOME inteox 7000i - Overheating

AUTODOME inteox 7000i - Overheating


SYMPTOMS:

  1. The Dashboard has a Maximum temperature that exceeds 80 Degrees C.
    1. The Diagnostic log will also report this as the "Highest Temperature", will increase the "Exceed high temperature" counter by the amount of times that the internal temperature exceeded 80 Deg C, and will track the hours/minutes that it exceeded 80 Deg C as " Device temp max period".
  2. The camera will display "Status 8" when the internal temperature is above 80 Deg C.

Possible causes and solution(s)

  • Causes

As part of QMM routine monitoring of field returns, a potential overheating issue for the AUTODOME IP inteox 7000i cameras was observed.

A malfunction in one of the software components controlling the camera's heater was identified on the version 8.12.0005. The malfunction only occurs when the camera is exposed to specific conditions. To eliminate any inconvenience to our customers, FW 8.12.0010 fixes this malfunction. It is available on the Bosch Security Download Store.

  • Solution

The camera FW must be upgraded. to 8.12.0010 or higher.

Do not  connect the AUTODOME inteox 7000i camera to the network and configure it while it is still inside the packaging/box.


NOTE: FW version 8.12.0010, is a prerequisite for the process of upgrading to firmware versions 8.40.00029 or higher.