How to stop 'rtp.p_type 97' (OSD or Video Authentication packet) on a CPP4 and CPP7.3

How to stop 'rtp.p_type 97' (OSD or Video Authentication packet) on a CPP4 and CPP7.3


Causes and solution(s)

In some occasions, you can have an unwanted "rtp.p_type 97" packed in your video stream.
this "rtp.p_type 97" packed can cause on some decoder Brands (for example Barco) a memory leak.

This article describes the behavior of "rtp.p_type 97" for the following 2 platforms:

  • CPP4: for example on the MIC IP starlight 7000 HD, the "rtp.p_type 97" is always active and can only be de-activated with an RCP command
  • CPP7.3: for example on the MIC IP starlight 7000i, it can be switched on when using Video authentication, but after switch off, the camera needs a restart


How to turn ON/OFF for CPP4 moving camera

Payload Type 97 - RCP+ command to disable/enable the generation and transmission of those packets:

RCP+ CONF_PIC_INFO


Tag CodeNumDes

Message

SNMP Support

0x0b8enonono

Data typeAccess Level

Description

Readt_octetaccess_right_minimal

enables/disables the generation of pic info packets
(payload type 97)

Writet_octetaccess_right_serviceenables/disables the generation of pic info packets
(payload type 97) 

This RCP+ command was added and available since firmware version 5.80 and per the RCP+ documentation it is still applicable for CPP4 firmware version 7.10.

After sending this command, the “rtp.p_type 97" packet stops

  • Off> http://ipaddress/rcp.xml?command=0x0b8e&type=T_OCTET&direction=WRITE&payload=0x00&num=1
  • On> http://ipaddress/rcp.xml?command=0x0b8e&type=T_OCTET&direction=WRITE&payload=0x01&num=1

Note:

  • As its on by default, it will also turn back on after factory reset
  • Once it is turned off, it will also remains off after a reboot


How to turn ON/OFF for CPP7.3 moving camera

When choosing the Video Authentication option "SHA-1" , "rtp.p_type 97" will be added to the video stream
But when you turn it OFF again "rtp.p_type 97" will remain ON and doesn't stop, until you have restarted the camera.

  • "rtp.p_type 97" stream should stop when switched off


Despite the fact of disabling OSD, telemetry feedback, timestamp, and watermarking, the “rtp.p_type 97” continues:


  • Solution

A camera reboot is required when an Authentication other than Watermark is toggled ON and then OFF.

Additional information:

"rtp.p_type 97" can contains OSD information like for example:

Title OSD: Sector or Shot Title
Camera OSD: Digital Zoom, Iris open/close, Focus near/far
OSD User defined 1
OSD User defined 2
OSD User defined 3
Time Information
Hash / Signature Entry





Related content

͏ ͏ Stay up to date

Get in touch

You are on

͏͏͏ ͏ Newsletter

Contact us
Support
Training

Bosch Building Technologies
Bosch worldwide>

All Bosch Apps
Apps and Tools>



© Bosch Sicherheitssysteme GmbH 2025, all rights reserved