How to stop 'rtp.p_type 97' (OSD or Video Authentication packet) on a CPP4 and CPP7.3
Causes and solution(s)
In some occasions, you can have an unwanted "rtp.p_type 97" packed in your video stream.
this "rtp.p_type 97" packed can cause on some decoder Brands (for example Barco) a memory leak.
This article describes the behavior of "rtp.p_type 97" for the following 2 platforms:
- CPP4: for example on the MIC IP starlight 7000 HD, the "rtp.p_type 97" is always active and can only be de-activated with an RCP command
- CPP7.3: for example on the MIC IP starlight 7000i, it can be switched on when using Video authentication, but after switch off, the camera needs a restart
How to turn ON/OFF for CPP4 moving camera
Payload Type 97 - RCP+ command to disable/enable the generation and transmission of those packets:
RCP+ CONF_PIC_INFO
Tag Code | NumDes | Message | SNMP Support | |
0x0b8e | no | no | no | |
Data type | Access Level | Description | ||
Read | t_octet | access_right_minimal | enables/disables the generation of pic info packets | |
Write | t_octet | access_right_service | enables/disables the generation of pic info packets (payload type 97) |
This RCP+ command was added and available since firmware version 5.80 and per the RCP+ documentation it is still applicable for CPP4 firmware version 7.10.
After sending this command, the “rtp.p_type 97" packet stops
- Off> http://ipaddress/rcp.xml?command=0x0b8e&type=T_OCTET&direction=WRITE&payload=0x00&num=1
- On> http://ipaddress/rcp.xml?command=0x0b8e&type=T_OCTET&direction=WRITE&payload=0x01&num=1
Note:
- As its on by default, it will also turn back on after factory reset
- Once it is turned off, it will also remains off after a reboot
How to turn ON/OFF for CPP7.3 moving camera
When choosing the Video Authentication option "SHA-1" , "rtp.p_type 97" will be added to the video stream
But when you turn it OFF again "rtp.p_type 97" will remain ON and doesn't stop, until you have restarted the camera.
- "rtp.p_type 97" stream should stop when switched off
Despite the fact of disabling OSD, telemetry feedback, timestamp, and watermarking, the “rtp.p_type 97” continues:
Solution
A camera reboot is required when an Authentication other than Watermark is toggled ON and then OFF.
Additional information:
"rtp.p_type 97" can contains OSD information like for example:
Title OSD: Sector or Shot Title
Camera OSD: Digital Zoom, Iris open/close, Focus near/far
OSD User defined 1
OSD User defined 2
OSD User defined 3
Time Information
Hash / Signature Entry
Related content
͏ ͏ Stay up to date |
Get in touch |
You are on |
---|---|---|
Bosch Building Technologies
|
͏ ͏ Corporate information |
Legal Notice |
Data Protection Notice |
California Privacy |
CCPA-and-Canadian-Privacy-Disclosure |
Terms of use |