Microsoft Security Update MS17-010 on Bosch Recording Station Appliance
Possible causes and solution(s)
Related Products
Bosch Recording Station Appliance (BRS)
Causes
Just installing Microsoft Security Patches on a BRS Appliance will cause a BSOD after reboot.
Solution
The following steps are necessary:
- Download and extract Superbmc driver (3186.zip)
- Copy Superbmc.sys to C:/Windows/System32/drivers (Replace the existing file)
- Restart BRS system
- Install Microsoft Security Patch
windows6.1-kb4012212-x86_6bb04d3971bb58ae4bac44219e7169812914df3f.msu
Restart BRS system
Notes
If the customer has already done the Microsoft Security Patches and got the BSOD (Blue Screen of Death) after reboot, what is the best way to remedy the situation?
There are two different ways to fix the BSOD on a BRS Appliance:
- Recovery from DOM
- Boot Windows in "Safe mode" (F8) and revert updates.
The above mentioned security update MS17-010 is also suggested to prevent other malware attacks, such as the Petya Ransomware.