How to make proper connections to the DS150i relays.
How to make proper connections to the DS150i relays.
What is the relay wiring color configuration when in A or B mode?
With the jumper in the A (fail safe) mode the relays are as follows:
- 1st Relay:
- Yellow wire is Common (C)
- Blue wire is Normally Closed (NC)
- Violet wire is Normally Open (NO)
- Second Relay:
- Grey wire is Common (C)
- Orange wire is Normally Closed (NC)
- Green wire is Normally Open (NO)
With the jumper in the B setting (fail secure) the relays are as follows:
- 1st Relay:
- Yellow wire is Common (C)
- Blue wire is Normally Open (NO)
- Violet wire is Normally Closed (NC)
- Second Relay:
- Grey wire is Common (C)
- Orange wire is Normally Open (NO)
- Green wire is Normally Closed (NC)