How to Setup Keyswitch Arming D4112/D6112 Panel

How to Setup Keyswitch Arming D4112/D6112 Panel

Overview

Set up of a D6112 panel to have keyswitch arming. D611 is required.

*Note -   D611 is no longermade.

Issue

Keyswitch arming the D6112 panel.

Solution

D6112 panel can use a D611 Key Switch Module.

The D611 connects to the panels serial device data wiring. (connects in series like a keypad)

Panel programming:

4.1 Device#     =    location in the series wiring of the serialdevice data

                              1,2,3,4.

4.2 D#Model   =   1

6.1 Combo3    =   8

Notes

D4112, D6112, and the D611 no longer made.