How to Use CMD 80 & CMD 81 D6412/D4412

How to Use CMD 80 & CMD 81 D6412/D4412

Issue

User has authority in all areas but when presses Command 80, Command Center gives error tone and says Area 1 Ok for all on.

Solution

CMD 80 (All Areas On) and CMD 81 (All Areas Off) must be enabled in programming in order to function.

1)  Using Remote Programming:

Go to Panel Wide Parameters; Global Open Close Options; Arming Options and find Enable Cmd 80 - All Areas All On, and Enable Cmd 81 - All Areas All Off and set both to Yes.

2)  Using Keypad Programming:

Go to Nibble 1259 and enter 12 to enable both CMD 80 and CMD 81.

Part numbers D4412, D6412, D625, D623