How to use Selective Zone Shunting D8112 Series

How to use Selective Zone Shunting D8112 Series

Issue

Selective zone shunting on the D8112 system.
 
Solution
 

To use Selective Zone Shunting:

1. Ensure that all zones are secure. The Alpha II display should show READY TO ARM.

2. Start the system exit delay by entering your personal passcode or an arming command which provides exit delays. The display alternates between ALL SECURE and EXIT NOW.

3. While the system is in the exit delay mode, again press the COMMAND bar. The Alpha II will display all of the zones that may be shunted. CAUTION: You are in the exit delay mode and only have a limited amount of time in which to complete this operation.

4. To prevent a zone from being armed, press the key that corresponds with the number of that zone. For example, simply press the 4 key and it disappears from the display and zone 4 will not arm with the rest of the system. During the exit time, if you decide that you want one of the zones you have bypassed to be armed with the rest of the system, press the corresponding key and the zone reappears in the display.

Part numbers D8112, D8112A, D8112E, D8112E1, D8112G, D8112G1, D8112G2