How to Use DX4010i WithD6412, D4412, DS7240, & DS7220 Panels

How to Use DX4010i WithD6412, D4412, DS7240, & DS7220 Panels

Issue

  1. Trouble connecting to the D4412 with RPS / RAM IV using the DX4010i.
  2. What dip switches need to be set to make the DX4010i connect to the panel?
  3. What type of cable is needed between the DX4010i and the Laptop or PC?

Solution

  1. RAMIV / RPS needs to be revision 3.6 or higher.
  2. Set the address 0 (Installer's mode) Dip Switches 6 and 8 in the off postion on the DX4010i.
  3. Use a NULL cable to connect the DX4010i to the Laptop or PC.
  4. For remote programming connection, use the RJ-16 to molex connector to the Aux / Data header.
  5. Lock the Installer or Reset Pin on the panel.
  6. In the RSP/ RAMIV Connection screen change the connection type from MODEM to ENHANCED DIRECT, then click connect.

*If connected to a D4412 panel and the address is set wrong on the DX4010i then a message of "INVALID RAM PASSCODE" may be generated.