Step-by-step guide


 Step 1: Select Controller  in "DevEdit- [System configuration]"


 Step 2: Left-click on Controller and select "New entrance"


 Step 3: Select drop-down in "New entrance"


 Step 4: Select entrance model "DM 03a Revolving door with entry and exit reader"


 Step 5: Select the "Man-trap option (check box)"


Step 6: Select reader types being used for inbound and outbound


Step 7: Repeat steps 1-6 to create the second set of readers for the Man-trap

Step 8: Select the first entrance 


Step 9: Select Terminals tab item which will display the both entrances created  for the man-trap



 Step 10:  Select a reader then select additional settings tab


Step 11:  Set Access sequence check to  option: 3 and repeat  for each reader in man-trap


 Step 12: Select the Areas icon and create 3 areas that  lead into the next area


 Step 13: User left click on "Man-trap-Area  set number of persons to 1


 Step 14: Select first Entrance  in the Man-trap and set location to Outside the default and Destination to the Man-Trap area


Step 15: Select second Entrance in the Man-trap and set location to the Man-trap area and the Destination to the Final destination for Man-trap


Link shown below is for the configuration manual showing how to physically wire a Man-Trap beginning on page 97: