Skip to end of banner
Go to start of banner

What to do with missing metadata in Milestone XProtect

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Version History

Version 1 Current »

Article status

EXTERNAL

Link to be provided outside of Bosch

When using Bosch plugins inside Milestone XProtect, you might run into issues with the Metadata stream.

Possible causes and solution(s)

  • Symptoms

    • Enhanced Metadata Plugin
      • The Bosch metadata rendering is not happening
      • No object classification is shown
    • Forensic Search Plugin
      • Search always bails out at the same point in time
      • or does not show results at all

  • Causes

Due to a bug in the Milestone Driver (up to device pack 12.7) the Bosch binary metadata stream is incompletely stored.


  • Solution

An easy workaround in this scenario is to change the Metadata streaming mode in XProtect from Bosch binary to 'Bosch binary & Onvif'. This can be set in the Metadata settings in the Milestone Management Client. A final fix needs to come from Milestone with a Device Pack update.