Note

In order to quickly offer a technical solution or to provide a professional advice for the next analysis steps, the technical support specialists need to get some general and basic information. Ticket content should always be in English and provided in a well summarized and structured way in order to be able to provide a quick and appropriate feedback. Not following the guideline will impact the processing time of the ticket.

Article status

EXTERNAL 

Link to be provided outside of Bosch

How-To

Check the boxes for which information is requested for the current issue. export the page as a PDF-file by clicking on the three dots on the top right of the page. This document can then be forwarded to the customer

General Information

  • Contact name (person) delivery 
  • Contact number (tel.) delivery 
  • Contact e-mail delivery 
  • Delivery location company name (co location) 
  • Street name 
  • House number 
  • Zip code 
  • City 
  • Country 
  • Specific directions for delivery (Reception, Warehouse… etc. ) 


Unit information

  •  Has the unit been registered using the registration information that was in the unit shipping box?
        (if not, please fill in the form, which can be downloaded from here)
  • Unit information
    • Model Name
    • Full Model Number
    • Serial Number
    • Mat/N
  • Clear picture of the faulty unit label so that the serial number is visible


Logging Information



Symptom specific Information

  • Detailed problem description

Faulty HDD

Faulty SSD

  • Picture of the RAID 1 status
    • E.g.: Start the unit and press F7 during the BIOS power-on-self-test and afterwards select Raid 1 setup:

SMC unit not booting

  • Video with the front of the unit during the boot sequence, where the beep codes are audible and the LEDs on the front of the unit are visible;
  • Video of the screen
  • Information on whether the unit worked before or not

SMC unit does not power up

  • Pictures with back LEDs from the power supply
    • E.g.:
  • Picture with the front panel of the unit
    • E.g.:
  • What is the result if checking with another power cord?


Why does the Central Technical Support team ask for the following information?


  1. IPMI logs are required for/ when, for example:
    • Device does not power up, No video is shown on the Monitor, BIOS issues
  2. Super Doctor logs and print screens are required for/ when, for example:
    • Power Supply failure, Unit overheating. Can be requested to see the general health of the unit
  3. MegaRaid logs are required for/ when, for example:
    • HDD failure, RAID controller failure, Windows cant detect the HDD’s
  4. Picture with the front panel of the unit is required for/ when, for example:
    • This is requested in general to see the status of the unit  (LED’s). E.G. Red LED is on next to a faulty HDD, RED LED indicates a power  delivery issue,
  5. Picture from the MegaRaid Storage Manager is required for/ when, for example:
    • HDD failure, RAID controller failure, Windows cant detect the HDD’s, RAID volume issues
  6. LSIget data capture script Manager is required for/ when, for example:
    • Same as point 5, but is requested only by Central Technical Support team in certain cases for deep investigations
  7. Picture of the RAID 1 status is required for/ when, for example:
    • Unit can't boot into Windows, one SSD failed, Entire RAID 1 failed
  8. Pictures with back LEDs from the power supply is required for/ when, for example:
    • Power Supply failure, Unit does not power up