Skip to end of banner
Go to start of banner

Troubleshooting Alarm Notification in Cloud VMS Operator Interface

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Version History

Version 1 Next »

Article status

EXTERNAL

Link to be provided outside of Bosch

Possible causes and solution(s)

This document contains information on what situations might happen if no alarm events from a Live Intervention, Video Verification or Virtual Assistant services appear in the Cloud VMS Operator Interface and how to advise.


IssueCauseSolution
No alarm event appears in event list. 

Maintenance Mode is enabled for related Site

In Cloud VMS the Maintenance Mode allows the 'Technician' (Installer) to access the cameras of the related Site for maintenance purposes from Camera Quick Install website. Furthermore the Config Agent or Integrator can upgrade the firmware and save or load a device configuration from Configuration website.

If the Maintenance Mode is enabled for a Site, the alarm processing is disabled.

As Integrator or Config Agent, check in Configuration website (enter Account, select Site) if Maintenance Mode is enabled for the related Site.

Disable the Maintenance mode, then the new alarm appears in event list

No alarm appears in event list. Site is disarmed

In Cloud VMS there are different ways to arm a Site:

  • Always armed (default setting)
  • Manually armed (Site can be armed / disarmed by Config Agent or Integrator, Alarm Agent, or by mobile User (customer, from mobile device running Site Monitor App).
  • Armed by camera input (Site can be armed / disarmed by physical input of an IP device)

If the Site is disarmed, the alarm processing is disabled.

As Integrator or Config Agent, check in Configuration website (enter Account, select Site) if the related Site is disarmed.

Arm the Site (manually or by camera input), then the new alarm appears in event list.

No alarm appears in event list. 

Service is snoozed

In Cloud VMS the Alarm Agent can snooze services for a certain time period (e.g. 10 minutes) to temporarily stop permanent alarm processing.

If the service is snoozed, the alarm processing is disabled.

As Integrator or Config Agent, check in Configuration website (enter Account, select Site) if Alarm Processing is disabled for the related Site.

Enable Alarm Processing, then the new alarm appears in event list.

No alarm appears in event list. 

Schedule is not active

In Cloud VMS an Service Scenario is active within a certain configured Schedule (e.g. Day, Night, always). If the alarm trigger is not within the active time of the configured Schedule, the configured Service won't be executed.

As Integrator or Config Agent, check in Configuration website (enter Account, enter Site, select Services) if the correct Schedule is selected in 'Arming Period' field.

Check in Configuration website (enter Account, select Schedules) if the above selected Schedule covers the current time (blue cells mark active time periods).





ADVANCED section

Please contact CTS / SG or GK team to view this section from draft space, if necessary


Information below is for CTS, SG, GK reference and must be kept internal only.

If you are part of CTS, SG or GK team, please hide this section when you have finished using this article!


This section will not be published externally and / or automatically downloaded in the PDF file!


  • No labels