The iris works by limiting the amount of light that hits the image sensor.
Too little light can make everything dark, and too much light can make the image overexposed or washed out.
The MinIris and MaxIris values could be configured when the camera is mounted and installed in specific lighting conditions.
Therefore, it’s important to have an iris that’s specifically suited for your camera’s location.

Scenario

The MinIris and MaxIris values cannot be read-out from the camera.
Two fields: MinIris and MaxIris are missing from the Exposure node from the GetImagingSettingsResponse SOAP document.

Solution

First of all, you need to check if the software you are using it is fully interoperable with all third-party ONVIF Profile T conformant IP devices, such as cameras and encoders.

  • The MIC IP Starlight 7100i camera conforms to the specifications for ONVIF Profile S and ONVIF Profile G.
  • For H.265 configuration, the camera also supports Media Service2, which is part of ONVIF Profile T

According to the ONVIF™Imaging Service Specification and to the ONVIF Profile Feature overview, Iris is part of the "Imaging settings" and "Imaging setting" belongs to ONVIF Profile T.

Iris is part of Imaging settings.png

2020-06-26_10h53_05.png

If you test this in the ONVIF Device Test Tool version 19.12 rev. 5581 you will see that the option for this camera type (MIC IP Starlight 7100i) will pass successfully, as can be seen in the following screenshots:

2020-06-24_09h32_32.png


Also note that thi stest report contains the Min and Max values


Why MinIris and MaxIris are missing from the Exposure node from the GetImagingSettingsResponse SOAP document?
According to the official documentation from ONVIF, MinIris and MaxIris are missing because this is an optional float.
Therefore, the GetOptionsResponse may contain the MinIris and MaxIris values such as the following:

<tt:Iris>

<tt:Min>1.00</tt:Min>

<tt:Max>13.00</tt:Max>

</tt:Iris>





Nice to do:

In order to receive min and max iris from GetOptions, you can also try updating the camera to the latest firmware.