Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.




Scroll ignore Scroll ignoreArticle statuskb-articleINLINE

Greenexternal  

Link to be provided outside of Bosch

kb-articleINLINE

Yellowinternal

Internal document. This article cannot be provided outside of Bosch.

Step-by-step guide

Steps to focusing a Box camera:

  • Start by opening the Lens Wizard in the Installer Menu

  • Set the Back Focus to the Center position
    • By pressing Center Button
      • When the Focus position is finished it will be centered at 500.
    • Set the Zoom manually (Wide to Tele) to customize the image boundaries.
    • Then focus the lens manually
      • By physically adjusting the focus on the lens body.
      • Adjust the manual lens focus as good as physically possible.
    • Finally, press ‘Full Range’ to allow the camera to auto focus for the optimum image focus.


      • The objective is to have the camera's focus position set near the Focus Position of 500 position.
        • If  the focus position is off center like the below image, the camera/lens could have problems focusing from edge to edge.

 

    • To focus on a specific area
      • Select the area by dragging the Rectangle to shade the specific area that you want to focus.
      • Then press Local Range to focus on the specific area.


Note
titleMechanical Tilt:

The Box camera can also experience problems with focus when the tilt of the camera and the tilt of the lens react together to create focus limitation.

  • To fix this, try rotating the lens 90° or 180° and refocus the camera.
Scroll ignore
advancedINLINEgreenINLINE

MANDATORY --> after finishing this article, if you wrote advanced content in this section , you must to manually add the "advanced" label  This action is required to indicate that this article contains ADVANCED instructions for CTS/ SG or GK.

DO NOT CHANGE ANYTHING IN THIS SECTION!

advanced section
Please contact CTS / SG or GK team to view this section from draft space, if necessaryadINLINE

IMPORTANT! --> the content itself from here will be not displayed. The content from here will be displayed only when the "ad" label will be set after article creation. Only CTS/ SG or GK are allowed to use "ad" label.

PLEASE do not set "ad" label from beginning. Use it only when you need this info and REMOVE the "ad" label when finished!

Information below is for CTS, SG, GK reference and must be kept internal only.

If you are part of CTS, SG or GK team, please hide this section when you have finished using this article!

DO NOT CHANGE ANYTHING IN THIS SECTION!

This section will not be published externally and / or automatically downloaded in the PDF file!

Type your text/ advanced information here

Please write here the statement/answer/explanation

Add pictures, if necessary






Scroll only
scroll-pdftrue
scroll-officetrue
scroll-chmtrue
scroll-docbooktrue
scroll-eclipsehelptrue
scroll-epubtrue
scroll-htmltrue


You are using an Offline Version of these Article, please ensure to regularly check the corresponding online article on the Bosch Building Technologies Knowledge Base for any updates. Use the date and version information of the document as reference.

This is  created  

Check for Updateprimaryhttps://community.boschsecurity.com/t5/Bosch-Building-Technologies/ct-p/bt_community