How-to: Serial Tunnel

How-to: Serial Tunnel

Issue

A serial connection is needed but the distance between the devices is to far for a serial cable.

Solution

These are the channel 1 settings for using 2 UDS-10s to make a serial tunnel over a TCP/IP network:

UDS10 Settings for a Serial Tunnel

UDS-10 #1
Baudrate 9600
I/F Mode  4C
Flow  00
Port  10001
ConnectMode  C5
Auto Increment Source Port N
Remote IP Address  10.10.10.10 (this is the IP of the 2nd UDS-10)
Remote Port  10001
DisconnectMode 00
FlushMode 00
DisConnTime 00:00
SendChar 1  00
SendChar 2  00

UDS-10 #2
Baudrate 9600
I/F Mode  4C
Flow  00
Port  10001
ConnectMode  C0
Auto Increment Source Port  N
Remote IP Address  10.10.10.20 (this is the IP of the 1st UDS-10)
Remote Port  10001
DisconnectMode 00
FlushMode 00
DisConnTime 00:00
SendChar 1  00
SendChar 2  00