How to Arm Shared Area

How to Arm Shared Area

 Overview

Shared area arming requires all Associate areas to be armed. As soon as the last Associate area is armed, the Shared area begins its arming sequence automatically. Shared areas cannot be armed by passcode, keyswitch, sub-controls or Remote Account Manager. To allow faulted points to be displayed at associated areas, the shared and associate areas must share the same account number.

Issue

Shared area will not arm when all other associate areas are armed.

Solution

Shared area will only arm when all other associate areas are MASTER armed.

Requires all Associate areas to be MASTER armed. As soon as the last Associate area is armed, the Shared area begins its arming sequence automatically. Shared areas cannot be armed by passcode, keyswitch, sub-controls or Remote Account Manager.

Shared area will NOT follow any other armed state.

Part numbers D7212B, D9112B, D7212B1, D9112B1, D7212, D7412, D9112, D9124, D9412, D7412G, D9124G, D9412G, D7412GV2, D9124GV2, D9412GV2, D7412GV3, D9412GV3, D7412GV4, D9412GV4,

 