BRS NetLimiter may become not registered
Possible causes and solution(s)
Causes
Related Products
Bosch Recording Station (BRS) version 8.9 and later
The UDP tunneling cannot be configured on BRS.
Network cards are grayed out.
Solution
Under certain circumstances BRS NetLimiter may become not registered.
The network cards are not shown in Configuration > Security and Network > Network settings.
In that case, register BRS NetLimiter manually:
1. Close BRS application
2. Control Panel > System and Security > Administrative Tools > Services > Bosch Networking Service
a) Set "Startup Type" to "disabled"
b) Stop service
c) In a console window with administrative rights, enter "C:\Program Files\Bosch\Recording Station\NetLimiterServer" /service
d) Set "Startup Type" to "Automatic"
e) Start service
3. Start BRS application