ccc.exe - memory leak on Divar IP 7000 R2
ccc.exe - memory leak on Divar IP 7000 R2
Possible causes and solution(s)
Overview
Memory leak on a Divar IP 7000 R2 triggered by Catalyst Control Center.
Causes
Under some circumstances the software Catalyst Control Center (ccc.exe) occupies 100% of the virtual memory on a Windows Server 2012 system.
Loglines from Windows event log showing the memory issue:
Warning 15.09.2017 02-30-37 Microsoft-Windows-Resource-Exhaustion-Detector (3) NT AUTHORITY\SYSTEM mydivar |
---|
->Windows successfully diagnosed a low virtual memory condition. The following programs consumed the most virtual memory: CCC.exe (10744) |
---|
Solution
There are two different ways to solve the issue:
1. delete ccc manually from the registry and restart the Divar IP 7000 R2.
OR:
2. Update your Divar IP with upcoming BVMS Appliance version 8.0.x
Notes
Issue is fixed inside upcoming BVMS Appliance version 8.0.x
, multiple selections available,
Related content
Why does DIVAR IP 7000 R2 display the message 'The memory could not be read'?
Why does DIVAR IP 7000 R2 display the message 'The memory could not be read'?
More like this
How to create Bosch MVS (mobile video service) memory dump?
How to create Bosch MVS (mobile video service) memory dump?
More like this
Bosch Security Advisories - PSIRT (Product Security Incident Response Team)
Bosch Security Advisories - PSIRT (Product Security Incident Response Team)
More like this
͏ ͏ Stay up to date |
Get in touch |
You are on |
---|---|---|
Bosch Building Technologies
|
͏ ͏ Corporate information |
Legal Notice |
Data Protection Notice |
California Privacy |
CCPA-and-Canadian-Privacy-Disclosure |
Terms of use |