This article lists the initial troubleshooting steps for issues with ONVIF cameras, added to BVMS system as Live Only ONVIF cameras. The specific point in this scenario is VSG is not used.

Possible causes and solution(s)

  • Camera can't be added to device tree, or there are issues with live view from the camera

First points to check are if the camera in ONVIF Profile S compliant and if there are ONVIF specific settings that need to be enabled that the camera.


  • Solution

1. Check if the camera is ONVIF compliant and if it is tested in the respective BVMS version. (link to how to article - How to check if a 3rd party camera is supported in BVMS?)

2. Check for vendor specific settings of the camera when using ONVIF:

  • ONVIF stream to be enabled?
  • ONVIF user to be created?

3. Try to add the camera to VSG and see if the same issue persist.
add as ONVIF if still no success add as RTSP camera to see if you have live video

4. After the above steps, reproduce the issue and provide to technical support:

  • Wireshark capture that covers the complete time of reproduction
  • Full screen recording (or Screenshots) of the reproduction, or clear list with the steps for reproduction
  • BVMS Configuration Collection from the Management Server



Scroll only
scroll-pdftrue
scroll-officetrue
scroll-chmtrue
scroll-docbooktrue
scroll-eclipsehelptrue
scroll-epubtrue
scroll-htmltrue


You are using an Offline Version of these Article, please ensure to regularly check the corresponding online article on the Bosch Building Technologies Knowledge Base for any updates. Use the date and version information of the document as reference.

This is created 

Check for Updateprimaryhttps://community.boschsecurity.com/t5/Bosch-Building-Technologies/ct-p/bt_community