Since VRM 4.10, we have reintroduced the Live & Replay pages in the VRM web GUI.

Please note: there is no PTZ control possible via the VRM web GUI, please use installed SW.

How to disable the Live and Replay page from the VRM web GUI

When you want to restrict Live & Replay to the installed Software like BVMS, Video Security Client, Genetec etc.

Step-by-step guide

There is a possibility to Hide the Live & Replay pages from the Web GUI via by adding a Reg Key (if not specified during the BVMS install/upgrade via command line parameter e.g. <Path>\BVMS_Setup.exe /v"HIDELIVEREPLAYPAGE=1"):

adINLINE

IMPORTANT! --> the content itself from here will be not displayed. The content from here will be displayed only when the "ad" label will be set after article creation. Only CTS/ SG or GK are allowed to use "ad" label.

PLEASE do not set "ad" label from beginning. Use it only when you need this info and REMOVE the "ad" label when finished!

Information below is for CTS, SG, GK reference and must be kept internal only.

If you are part of CTS, SG or GK team, please hide this section when you have finished using this article!

DO NOT CHANGE ANYTHING IN THIS SECTION!

This section will not be published externally and / or automatically downloaded in the PDF file!

Type your text/ advanced information here

Please write here the statement/answer/explanation

Add pictures, if necessary
  • PATH: "HKLM\Software\Wow6432Node\Bosch\VRM"
  • DWORD = HideLiveReplayPage
  • Default value Value = 0, set to any non-zero value will disable 1, will hide the Live/Replay page
Scroll ignoreadvancedINLINEgreenINLINE

MANDATORY --> after finishing this article, if you wrote advanced content in this section , you must to manually add the "advanced" label  This action is required to indicate that this article contains ADVANCED instructions for CTS/ SG or GK.

DO NOT CHANGE ANYTHING IN THIS SECTION!

advanced section
Please contact CTS / SG or GK team to view this section from draft space, if necessary
  • - setting the value to 0 will display the Live/Replay pages (by default the Live/Replay pages are visible)





Scroll only
scroll-pdftrue
scroll-officetrue
scroll-chmtrue
scroll-docbooktrue
scroll-eclipsehelptrue
scroll-epubtrue
scroll-htmltrue


You are using an Offline Version of these Article, please ensure to regularly check the corresponding online article on the Bosch Building Technologies Knowledge Base for any updates. Use the date and version information of the document as reference.

This is  created  

Check for Updateprimaryhttps://community.boschsecurity.com/t5/Bosch-Building-Technologies/ct-p/bt_community