Step-by-step guide:


Cloud VMS Alarm Management provides an AI Snapshot in the Operator Interface > Verification Mode, next to the Alarm Snapshot from the camera and the Smart Event Image.

Click the  button to display the AI snapshot.

Image RemovedImage Added

The AI Snapshots marks the detected object (moving person or vehicle) with a bounding box and shows the AI Score in dark red pink color.

Image RemovedImage Added

For example: An AI score of 1.00 means an AI alarm verification of 100% (see also Cloud VMS


See also Alarm Management Configuration > Service > AI Alarm Verification > AI Threshold for moving persons or vehicles).

If the AI score is above the configured AI Threshold, the AI alarm gets verified; if the AI score is below the configured AI Threshold, the AI alarm gets rejected.

The different color of the bounding box mark the detected object:

  • beige The moving object is detected by the camera's VCA (detected but not alarmed)
  • orange: The moving object is alarmed by the camera's VCA

  • dark red: the movig object is detected by the cloud's AI algorithm + AI Score

  • Image Removed

    See also: Cloud VMS Alarm Management Configuration: How to set up an AI Alarm Verification service?

    Scroll ignoreadvancedINLINEgreenINLINE

    MANDATORY --> after finishing this article, if you wrote advanced content in this section , you must to manually add the "advanced" label  This action is required to indicate that this article contains ADVANCED instructions for CTS/ SG or GK.

    DO NOT CHANGE ANYTHING IN THIS SECTION!

    advanced section
    Please contact CTS / SG or GK team to view this section from draft space, if necessaryadINLINE

    IMPORTANT! --> the content itself from here will be not displayed. The content from here will be displayed only when the "ad" label will be set after article creation. Only CTS/ SG or GK are allowed to use "ad" label.

    PLEASE do not set "ad" label from beginning. Use it only when you need this info and REMOVE the "ad" label when finished!

    Information below is for CTS, SG, GK reference and must be kept internal only.

    If you are part of CTS, SG or GK team, please hide this section when you have finished using this article!

    DO NOT CHANGE ANYTHING IN THIS SECTION!

    This section will not be published externally and / or automatically downloaded in the PDF file!

    Type your text/ advanced information here

    Please write here the statement/answer/explanation

    Add pictures, if necessary






    Scroll only
    scroll-pdftrue
    scroll-officetrue
    scroll-chmtrue
    scroll-docbooktrue
    scroll-eclipsehelptrue
    scroll-epubtrue
    scroll-htmltrue


    You are using an Offline Version of these Article, please ensure to regularly check the corresponding online article on the Bosch Building Technologies Knowledge Base for any updates. Use the date and version information of the document as reference.

    This is  created  

    Check for Updateprimaryhttps://community.boschsecurity.com/t5/Bosch-Building-Technologies/ct-p/bt_community