In order to prevent security breaks, the PRA-ES8P2S network switch is by default not reachable via web interface.
If needed, it can be configured via the serial console port. Additionally via this console port, the web server can be activated, so the switch can be configured via the web GUI.

Please disable the web server after the configuration was completed!

This description is also available in the configuration manual v1.60, chapter 5.3.7.

Step-by-step guide

  • connect your PC to the Console Port of the powered switch, the PC most probably won't have a serial port, in that case use an USB-to serial convertor. The console port of the switch is a RS-232 serial port, but it is a RJ-45 socket. Here is the pinning of an adapter cable
    Image RemovedImage Removed
  • On the PC, start a terminal program like uCon or Putty.
  • Locate the COM Port of the converter (at Computer Management, Device Manager), in this example, it is COM5.
  • Setup the connection with following settings:
    Bits per second (BAUD): 115,200.
    Number of bits: 8.
    Parity: None.
    Stop bits: 1.
    Image RemovedImage Removed
  • Open the connection, "Welcome to L2 Management Switch" should appear
    Image Removed
  • Enter the default credentials from the manual. Username: Bosch, Password: mLqAMhQ0GU5NGUK.
  • A promt appears with switch#
  • To go to the settings, type "conf", press Enter.
  • To enable web server via https, type "ip https", press Enter. If neede also enable http, type "ip http".
  • Exit the settings, type "exit", press Enter.
  • Save the settings, type "save", press Enter. The Terminal window should look like this now:
    Image Removed
  • Reboot the switch, type "reboot", press Enter.
  • Now you can access the switch via web interface at Ip address https://169.254.255.1/
  • Log on via the known credentials (see step 6)
  • After the desired settings are done, disable the web server again like decribed above, but use the terms "no ip https" and "no ip http".
  • Scroll ignoreadvancedINLINEgreenINLINE

    MANDATORY --> after finishing this article, if you wrote advanced content in this section , you must to manually add the "advanced" label  This action is required to indicate that this article contains ADVANCED instructions for CTS/ SG or GK.

    DO NOT CHANGE ANYTHING IN THIS SECTION!

    advanced section
    Please contact CTS / SG or GK team to view this section from draft space, if necessaryadINLINE

    IMPORTANT! --> the content itself from here will be not displayed. The content from here will be displayed only when the "ad" label will be set after article creation. Only CTS/ SG or GK are allowed to use "ad" label.

    PLEASE do not set "ad" label from beginning. Use it only when you need this info and REMOVE the "ad" label when finished!

    Information below is for CTS, SG, GK reference and must be kept internal only.

    If you are part of CTS, SG or GK team, please hide this section when you have finished using this article!

    DO NOT CHANGE ANYTHING IN THIS SECTION!

    This section will not be published externally and / or automatically downloaded in the PDF file!

    Type your text/ advanced information here

    Please write here the statement/answer/explanation

    Add pictures, if necessary





    Scroll only
    scroll-pdftrue
    scroll-officetrue
    scroll-chmtrue
    scroll-docbooktrue
    scroll-eclipsehelptrue
    scroll-epubtrue
    scroll-htmltrue


    You are using an Offline Version of these Article, please ensure to regularly check the corresponding online article on the Bosch Building Technologies Knowledge Base for any updates. Use the date and version information of the document as reference.

    This is  created  

    Check for Updateprimaryhttps://community.boschsecurity.com/t5/Bosch-Building-Technologies/ct-p/bt_community