Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Scroll ignore

Scroll ignore
Article statuskb-articleINLINE

Greenexternal

Link to be provided outside of Bosch

kb-articleINLINE

Yellowinternal

Internal document. This article cannot be provided outside of Bosch.

Possible causes and solution(s)

  • Causes


BVMS Installer - Windows Pending Restart Message

The pop-up dialog window message: "Setup has detected a pending restart.  Please reboot the system and rerun the installation"  appears when attempting to run the valid BVMS windows installer package.

BVMS Installer Pending Restart Message

This is a known Windows specific problem when another (non-BVMS) installer does not properly manage its creation and deletion of the “PendingFileRenameOperations” registry key.

The most common user created way for this key value to be left resident in the system is when an installation prompts for a restart, yet the system is not expeditiously restarted.


  • Solution


A. Restart the affected workstation
B. If the issue still persists, delete the orphaned "PendingFileRenameOperations" registry key value

  1. Open a registry editor, such as Regedit.exe or Regedt32.exe.  
  2. Navigate to "HKLM\SYSTEM\CurrentControlSet\Control\Session Manager\"
  3. In the right navigation pane, right-click the "PendingFileRenameOperations" key value and select delete
  4. Close Registry Editor.
  5. Run the software Installer again as Administrator


 
Note:  This message is not a Bosch product failure message. This is a problem within windows and it's registry clean-up handling.  This is a Windows work around. 

Scroll only
scroll-pdftrue
scroll-officetrue
scroll-chmtrue
scroll-docbooktrue
scroll-eclipsehelptrue
scroll-epubtrue
scroll-htmltrue

You are using an Offline Version of these Article, please ensure to regularly check the corresponding online article on the Bosch Building Technologies Knowledge Base for any updates. Use the date and version information of the document as reference.

This is  created  

Check for Updateprimaryhttps://community.boschsecurity.com/t5/Bosch-Building-Technologies/ct-p/bt_community