Scroll ignore |
---|
Scroll ignore |
---|
Link to be provided outside of Bosch Internal document. This article cannot be provided outside of Bosch |
For troubleshooting of VSDK based applications (ex. BVMS, BVC) sometimes development requests VSDK logging.
Typical scenarios for VSDK logs request are live view or play back issues.
Related Products:
BVC
BVMS
Workstations
Servers
Video SDK
This article explains how to collect Video SDK Logs for VSDK based applications.
Step-by-step guide
1. Enable VSDK logging
1.1 Create the directory C:\VSDK\Log.
- VSDK writes logs only when this directory exists
- In case it was already existing, there would be old logs. Delete them.
1.2 Enable specific VSDK log level. This is done by creating registry key in the registry directory VideoSDK5:
1.2.1 Click Start, type regedit in the Open box, and then click OK.
1.2.2 Locate the registry directory VideoSDK5 (if it doesn’t exist, create it)
- For 32 Bit system: HKEY_LOCAL_MACHINE\SOFTWARE\Bosch\VideoSDK5
- For 64 Bit system: HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Bosch\VideoSDK5
1.2.3. If no specific instructions are provided, create: "BVIPDebug" [DWORD] /[DWORD -32 bit] in 64 bit system. The possible values are:
- 0 - No changes
- 1 - Debug mode - set the value to 1
2. Reproduce the issue.
2.1. VSDK logs are overwritten fast, so once the issue is reproduced, close the application (BVMS, BVC, etc)
2.2. In case there is no application concerned, but the logs are written for a service (like MVS), you should stop the service in order the files to be written in the directory log and only then copy them (otherwise they will be empty).
- reproduce the issue
- stop the service (in case of MVS it is Bosch MVS BVMS Provider), otherwise you will have only empty files in the directory VSDL/logs. Once the service is stopped, the entries are filled in the log files
- VSDK/Log is ready to be collected
2.3. Write down short description of the issue (including IP address of the affected devices) and the timestamp of the issue.
3. Collect the logs
3.1. For BVMS always use BVMS Configuration Collector tool, it will collect also VSDK logs
3.2. For other VSDK applications copy the content of the directory C:\VSDK\Log.
3.3. For MVS always use BVMS BVMS Configuration Collector tool, it will collect also VSDK logs
4. Disable the VSDK logging.
4.1. Delete the registry key or set its value to 0
4.2. Delete the directory C:\VSDK\Log
Scroll only | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||
You are using an Offline Version of these Article, please ensure to regularly check the corresponding online article on the Bosch Building Technologies Knowledge Base for any updates. Use the date and version information of the document as reference. |